<><><><><><><><><><><><><> 9 FMT-150B/C/D 9 BY Draco NOTA: O SCRIPT FOI BASEADO NO MESMO PUBLICADO PELA PHRACK 18 OS AUTORES NOS AUTORIZARAM A REALIZAR AS DEVIDAS MUDAN€AS NO SCRIPT..................... FMT-150 ‚ um sistema que gerencia o uso conjunto de alarmes e afins. FMT-150 16 outputs sao definidos por: OUTPUT ALARME OUTPUT ALARME ------ ------ ------ ------ 1 BAY MAJOR 9 MI3 ALARM #3 2 BAY MINOR 10 HSA ALARM 3 OPT A FAIL 11 HSB ALARM 4 OPT B FAIL 12 DS1 GRP FAIL 5 STX TX 13 SYSTEM ID CLLI 6 STS RX 14 COMM. EQUIP. ALARM 7 M13 ALARM #1 15 NODE #1 CO 8 M13 ALARM #2 16 NODE #2 REMOTE Ele prove 32 pontos de alarmes separados. Os primeiros 16 pontos com exce‡ao do ponto 13 um pin block multiplo, que prove x-conec‡oes.. Ver pin.......... OS-35A FMT-150 System ------ -------------- PIN 17 SYSTEM 1 PIN 18 SYSTEM 2 : : : : PIN 31 SYSTEM 15 PIN 32 SYSTEM 16 Sistemas que usam FMT-150 sao monitorados 24 horas por dia, sao usados geralmente em shoppings... Estes sistemas em sua maioria sao monitorados via modem....... ----------------------Corte aqui Procomm Script para Accessar FMT-150B/C/D ;********************************************************************** ;* * ;* FMT150.CMD Version 5.01 1998 * ;* Destrua todas versoes anteriores a este programa * ;* * ;* NOTE: Procomm e um produto da Datastorm Technologies * ;* * ;* Devidamente Licenciado para FW - Corporation 100% Dark Side Brazil * ;* Todas as altera‡oes foram executadas por Jungle_Boy e Draco * ;* * ;********************************************************************** ; ; O script FMT150.CMD escreve automaticamente a performance da ; configura‡ao dos comandos de Northern Telecom FMT-150 fiber ; optic multiplexer. Especificamente o SCRIPT completa os 125 ; comandos de configura‡ao (performance, alarmes, erros de ; conexao). Este programa ‚ compativel com FMT-150 MCU NT7H90XE. ; ; Requerimentos: ; 1) Terminal Toshiba T1000. ; 2) Cabo serial e adaptadores. ; 3) Procomm disk com arquivo FMT150.CMD. ; ; Processo para usar: ; 1) Remova o disco do drive, resete o pc. Quando o prompt do DOS ; insira o PROCOMM disk no drive. ; Entre com "A:" + ; 2) Digite "FIXPRN" + . ; 3) Digite "PROCOMM" + . ; 4) Mantenha pressionado tecla down, pressione a tecla the ; e selecione FMT-150 no menu ; 5) Para ganhar o acesso ao MCU (pressione the 3 vezes). ; 6) Uma vez logado, resete o MCUe entre em "M(aitenance) "R"(eset) ; "*"(all) + ; 7) Ganhe acesso ao MCU com os passos 3 & 4 ; 8) Selecione o SCRIPT e aperte simultaneamente. ; 9) Quando o prompt surgir digite "FMT150" + . ; ;SN051690000 ;REFNO=5.00 CLEAR PAUSE 1 ALARM 1 MESSAGE " " MESSAGE " *************************************************" MESSAGE " * *" MESSAGE " * FMT-150 MCU NT7H90XC\CA CONFIGURATION PROGRAM *" MESSAGE " * MCU NT7H90XE\EA CONFIGURATION PROGRAM *" MESSAGE " * *" MESSAGE " * VERSION 5.00 1998 *" MESSAGE " * *" MESSAGE " * MICHIGAN BELL TELEPHONE COMPANY *" MESSAGE " * A DIVISION OF AMERITECH *" MESSAGE " * *" MESSAGE " * LICENSED FOR FW - CORPORATION *" MESSAGE " * *" MESSAGE " *************************************************" MESSAGE " " MESSAGE " " MESSAGE " ....TO EXIT THIS PROGRAM AT ANY TIME, PRESS ...." PAUSE 3 ALARM 1 ;VARIABLE DOCUMENTATION ;S0=CLLI A USER INPUT ;S1=CLLI B USER INPUT ;S2=CLLI LOCAL USER INPUT ;S3=YEAR 2 DIGIT USER INPUT ;S4=MONTH 2 DIGIT USER INPUT ;S5=DAY 2 DIGIT USER INPUT ;S6=HOUR 2 DIGIT USER INPUT ;S7=MINUTE 2 DIGIT USER INPUT ;S8=SYSTEM ID & USER RESPONSE USED TO CONTROL PROGRAM FLOW ;S9=SYSTEM NUMBER LABEL1: ; note the following statement was superseded in version 4.10 by VPRINT ;DOS "MODE LPT1:=COM2:" ; REQUIRED TO TURN PRINTER ERROR OFF ; following flushes the "RUB" buffer TRANSMIT "^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H" CLEAR LOCATE 10,2 MESSAGE "Entre com o CLLI code para LOCALIZAR A (C.O.) use 8 ou 11 characteres:" LOCATE 12,2 GET S0 11 ;CLLI A MESSAGE " " CLEAR LOCATE 10,2 MESSAGE "Entre com o CLLI code para LOCALIZAR B (REMOTE) use 8 ou 11 characteres:" LOCATE 12,2 GET S1 11 ;CLLI B MESSAGE " " CLEAR LOCATE 10,2 MESSAGE "Entre com o CLLI code para VOCE localizar using use 8 ou 11 characteres:" LOCATE 12,2 GET S2 11 CLEAR LOCATE 8,2 MESSAGE "Entre system ID sem 'MI', por exemplo ALBNMN-JCSNMN." LOCATE 10,2 GET S8 13 LOCATE 13,2 MESSAGE "Entre com o numero do sistema, por exemplo 1201 / T3X." LOCATE 15,2 GET S9 15 TRANSMIT "CGNS" TRANSMIT "`"" TRANSMIT S8 TRANSMIT "`"" TRANSMIT "!" CLEAR LOCATE 6,2 MESSAGE "Entre com a data de hoje." LOCATE 8,2 MESSAGE "Entre com os dois digitos do ano + " LOCATE 8,34 GET S3 2 ; 2 DIGIT YEAR LOCATE 10,2 MESSAGE "Entre com os dois digitos do mes + . Use 0's if required." LOCATE 10,58 GET S4 2 ; 2 DIGIT MONTH LOCATE 12,2 MESSAGE "Entre com os dois digitos do dia + . Use 0's if required." LOCATE 12,56 GET S5 2 ; 2 DIGIT DAY CLEAR LOCATE 6,2 MESSAGE "Entre com a hora." LOCATE 8,2 MESSAGE "Entre com os dos dogotos da hora + . Use 0's if required." LOCATE 8,57 GET S6 2 ; 2 DIGIT HOUR LOCATE 10,2 MESSAGE "Entre com os dois digitos do minuto + . Use 0's if required." LOCATE 10,59 GET S7 2 ; 2 DIGIT MINUTE CLEAR ;SET TIME DP3025 TRANSMIT "CT" TRANSMIT S6 TRANSMIT " " TRANSMIT S7 TRANSMIT " !" PAUSE 1 KFLUSH RFLUSH CLEAR ;PROMPT THE USER TO CHECK INPUTS FOR LOCATIONS LOCATE 1,2 MESSAGE "Por favor verifique as informa‡oes." LOCATE 4,2 MESSAGE "LOCALIZAR A CLLI CODE = " LOCATE 4,26 MESSAGE S0 LOCATE 6,2 MESSAGE "LOCALIZAR B CLLI CODE = " LOCATE 6,26 MESSAGE S1 LOCATE 8,2 MESSAGE "LOCAL LOCALIZAR CLLI CODE =" LOCATE 8,29 MESSAGE S2 LOCATE 10,2 MESSAGE "SYSTEM ID = " LOCATE 10,17 MESSAGE S8 LOCATE 12,2 MESSAGE "SYSTEM NUMBER = " LOCATE 12,21 MESSAGE S9 LOCATE 17,2 MESSAGE "ESTA INFORM€AO CORRETA? Y/N + " LOCATE 17,44 GET S8 1 SWITCH S8 CASE "Y" ;DO NOTHING ENDCASE DEFAULT GOTO LABEL1 ; JUMP TO TOP AND ENTER INFORMATION AGAIN ENDCASE ENDSWITCH CLEAR LOCATE 8,15 MESSAGE "NAO APERTE NENHUMA TECLA ATE A CONFIGURA€AO ESTAR COMPLETA" LOCATE 10,15 MESSAGE "OK PROSSIGA" ALARM 1 PAUSE 2 ;SET DATE DP3024 TRANSMIT "CD" TRANSMIT S3 TRANSMIT " " TRANSMIT S4 TRANSMIT " " TRANSMIT S5 TRANSMIT " !" PAUSE 1 ;NAME NODE 1 USING CENTRAL OFFICE CLLI CODE TRANSMIT "CGNN1 " TRANSMIT "`"" TRANSMIT S0 TRANSMIT "`"" TRANSMIT "!" ;NAME NODE 2 USING REMOTE CLLI CODE TRANSMIT "CGNN2 " TRANSMIT "`"" TRANSMIT S1 TRANSMIT "`"" TRANSMIT "!" ;DEFINE SITE TRANSMIT "CGS1 1 2 !" ;TRANSMIT "`"" ;TRANSMIT S0 ;TRANSMIT "`"" ;TRANSMIT S1 ;TRANSMIT " " ;TRANSMIT "!" ;CONFIGURE CUSTOMER OUTPUT POINTS DP3013 TRANSMIT "CGNO1 " TRANSMIT "`"BAY MINOR`"" TRANSMIT "!" TRANSMIT "CGNO2 " TRANSMIT "`"BAY MAJOR`"" TRANSMIT "!" TRANSMIT "CGNO3 " TRANSMIT "`"OPT A FAIL`"" TRANSMIT "!" TRANSMIT "CGNO4 " TRANSMIT "`"OPT B FAIL`"" TRANSMIT "!" TRANSMIT "CGNO5 " TRANSMIT "`"STX TX`"" TRANSMIT "!" TRANSMIT "CGNO6 " TRANSMIT "`"STX RX`"" TRANSMIT "!" TRANSMIT "CGNO7 " TRANSMIT "`"M13 ALARM #1`"" TRANSMIT "!" TRANSMIT "CGNO8 " TRANSMIT "`"M13 ALARM #2`"" TRANSMIT "!" TRANSMIT "CGNO9 " TRANSMIT "`"M13 ALARM #3`"" TRANSMIT "!" TRANSMIT "CGNO10 " TRANSMIT "`"HSA ALARM`"" TRANSMIT "!" TRANSMIT "CGNO11 " TRANSMIT "`"HSB ALARM`"" TRANSMIT "!" ;TRANSMIT "CGNO12 " ;TRANSMIT "`"DS1 GRP FAIL`"" ;TRANSMIT "!" TRANSMIT "CGNO13 " TRANSMIT "`"" TRANSMIT S9 TRANSMIT "`"" TRANSMIT "!" TRANSMIT "CGNO14 " TRANSMIT "`"COM EQUIP ALRM`"" TRANSMIT "!" TRANSMIT "CGNO15 " TRANSMIT "`"NODE #1 CO`"" TRANSMIT "!" TRANSMIT "CGNO16 " TRANSMIT "`"NODE #2 REMOTE`"" TRANSMIT "!" ;DELETE ALL EXISTING CUSTOMER OUTPUTS TRANSMIT "CGO1 D*!" TRANSMIT "CGO2 D*!" TRANSMIT "CGO3 D*!" TRANSMIT "CGO4 D*!" TRANSMIT "CGO5 D*!" TRANSMIT "CGO6 D*!" TRANSMIT "CGO7 D*!" TRANSMIT "CGO8 D*!" TRANSMIT "CGO9 D*!" TRANSMIT "CGO10 D*!" TRANSMIT "CGO11 D*!" TRANSMIT "CGO12 D*!" TRANSMIT "CGO13 D*!" TRANSMIT "CGO14 D*!" TRANSMIT "CGO15 D*!" TRANSMIT "CGO16 D*!" ;CUSTOMER OUTPUTS 1-2 TRANSMIT "CGO1 AS1 G100 !" TRANSMIT "CGO2 AS1 G120 !" ;CUSTOMER OUTPUTS 3-9 TRANSMIT "CGO3 AS1 G107 !" TRANSMIT "CGO4 AS1 G108 !" TRANSMIT "CGO5 AS1 G101 !" TRANSMIT "CGO5 AS1 G102 !" TRANSMIT "CGO5 AS1 G103 !" TRANSMIT "CGO6 AS1 G104 !" TRANSMIT "CGO6 AS1 G105 !" TRANSMIT "CGO6 AS1 G106 !" TRANSMIT "CGO7 AS1 G109 !" TRANSMIT "CGO8 AS1 G110 !" TRANSMIT "CGO9 AS1 G111 !" ;CUSTOMER OUTPUTS 10-11 TRANSMIT "CGO10 AS1 M1 MH18 !" TRANSMIT "CGO10 AS1 M2 MH18 !" TRANSMIT "CGO10 AS1 M3 MH18 !" TRANSMIT "CGO11 AS1 M1 MH19 !" TRANSMIT "CGO11 AS1 M2 MH19 !" TRANSMIT "CGO11 AS1 M3 MH19 !" ;TRANSMIT "CGO12 AS1 M1 1H2 !" ;TRANSMIT "CGO12 AS1 M2 1H2 !" ;TRANSMIT "CGO12 AS1 M3 1H2 !" ;TRANSMIT "CGO12 AS1 M1 1H3 !" ;TRANSMIT "CGO12 AS1 M2 1H3 !" ;TRANSMIT "CGO12 AS1 M3 1H3 !" ;CUSTOMER OUTPUT 13, 14 TRANSMIT "CGO13 AS1 G100 !" TRANSMIT "CGO13 AS1 G120 !" TRANSMIT "CGO14 AS1 G112 !" ;CUSTOMER OUTPUTS 15, 16 TRANSMIT "CGO15 AN1 G100 !" TRANSMIT "CGO15 AN1 G120 !" TRANSMIT "CGO16 AN2 G100 !" TRANSMIT "CGO16 AN2 G120 !" ;SET TO AUTOMATIC CONTROL TRANSMIT "CGO1 CA!" TRANSMIT "CGO2 CA!" TRANSMIT "CGO3 CA!" TRANSMIT "CGO4 CA!" TRANSMIT "CGO5 CA!" TRANSMIT "CGO6 CA!" TRANSMIT "CGO7 CA!" TRANSMIT "CGO8 CA!" TRANSMIT "CGO9 CA!" TRANSMIT "CGO10 CA!" TRANSMIT "CGO11 CA!" TRANSMIT "CGO12 CA!" TRANSMIT "CGO13 CA!" TRANSMIT "CGO14 CA!" TRANSMIT "CGO15 CA!" TRANSMIT "CGO16 CA!" ; ;DEFINE CUSTOMER OUTPUT 12 TRANSMIT "CGO12 D*!" TRANSMIT "CGNO12 " TRANSMIT "`"EXT ALM`"" TRANSMIT "!" TRANSMIT "CGO12 AN2 G118 !" ;also attach to pt 13 for alarm center ID TRANSMIT "CGO13 AN2 G118 !" ; ;DEFINE CUSTOMER INPUTS TRANSMIT "CGNI1 " TRANSMIT "`"SMOKE DET.`"" TRANSMIT "!" TRANSMIT "CGNI2 " TRANSMIT "`"SUMP PUMP`"" TRANSMIT "!" TRANSMIT "CGNI3 " TRANSMIT "`"OPEN DOOR`"" TRANSMIT "!" TRANSMIT "CGNI4 " TRANSMIT "`"AC PWR FAIL`"" TRANSMIT "!" TRANSMIT "CGNI5 " TRANSMIT "`"HI-LO TEMP`"" TRANSMIT "!" TRANSMIT "CGNI6 " TRANSMIT "`"RECT. FAIL`"" TRANSMIT "!" TRANSMIT "CGNI7 " TRANSMIT "`"BATT FLOAT`"" TRANSMIT "!" ; ;ADD CONDITIONS TO CUSTOMER OUTPUT 1 TRANSMIT "CGO1 AN2 SS5 !" TRANSMIT "CGO1 AN2 SS6 !" TRANSMIT "CGO1 AN2 SS7 !" ; ;ADD CONDITIONS TO CUSTOMER OUTPUT 2 TRANSMIT "CGO2 AN2 SS1 !" TRANSMIT "CGO2 AN2 SS2 !" TRANSMIT "CGO2 AN2 SS3 !" TRANSMIT "CGO2 AN2 SS4 !" ; ;PER JOE OLSZTYN SWITCHING SYSTEMS STAFF ;LEAVE PERFORMANCE MONITORING AT FACTORY DEFAULT ;DISABLE BLUE INSERTION FOR POINT TO POINT SYSTEMS ;IN A MULTIPOINT SYSTEM BLUE INSERTION SHOULD BE ENABLED. ;ENABLE ALARM LOGGER TRANSMIT "CAD!" ;DISABLE BLUE INSERTION NODE 1 DP3019 TRANSMIT "CN1 T1 BE!" TRANSMIT "CN1 T2 BE!" TRANSMIT "CN1 T3 BE!" ;ENABLE PARITY CORRECTION NODE 1 DP3020 TRANSMIT "CN1 T1 PE!" TRANSMIT "CN1 T2 PE!" TRANSMIT "CN1 T3 PE!" ;ENABLE RX OVERHEAD NODE 1 DP3021 TRANSMIT "CN1 T1 RE!" TRANSMIT "CN1 T2 RE!" TRANSMIT "CN1 T3 RE!" ;ENABLE TX OVERHEAD NODE 1 DP3022 TRANSMIT "CN1 T1 TE!" TRANSMIT "CN1 T2 TE!" TRANSMIT "CN1 T3 TE!" ;SIGNAL DEGRADE 10E-8 NODE 1 DP3158 TRANSMIT "CN1 T1 S8!" TRANSMIT "CN1 T2 S8!" TRANSMIT "CN1 T3 S8!" ;DISABLE BLUE INSERTION NODE 2 DP3019 TRANSMIT "CN2 T1 BE!" TRANSMIT "CN2 T2 BE!" TRANSMIT "CN2 T3 BE!" ;ENABLE PARITY CORRECTION NODE 2 DP3020 TRANSMIT "CN2 T1 PE!" TRANSMIT "CN2 T2 PE!" TRANSMIT "CN2 T3 PE!" ;ENABLE RX OVERHEAD NODE 2 DP3021 TRANSMIT "CN2 T1 RE!" TRANSMIT "CN2 T2 RE!" TRANSMIT "CN2 T3 RE!" ;ENABLE TX OVERHEAD NODE 2 DP3022 TRANSMIT "CN2 T1 TE!" TRANSMIT "CN2 T2 TE!" TRANSMIT "CN2 T3 TE!" ;SIGNAL DEGRADE 10E-8 NODE 2 DP3158 TRANSMIT "CN2 T1 S8!" TRANSMIT "CN2 T2 S8!" TRANSMIT "CN2 T3 S8!" ;LINE LEARN ALL MULTIPLEXERS BOTH NODES TRANSMIT "CN1 M1 L!" TRANSMIT "CN1 M2 L!" TRANSMIT "CN1 M3 L!" TRANSMIT "CN2 M1 L!" TRANSMIT "CN2 M2 L!" TRANSMIT "CN2 M3 L!" ;CONFIGURATION IS COMPLETE EXIT THE PROGRAM CLEAR ALARM 1 LOCATE 10,20 MESSAGE "......CONFIGURA€AO COMPLETA......" LOCATE 14,17 MESSAGE "CONTINUE COM A CONFIGURA€AO DA SE€AO 5" ALARM 2 PAUSE 5 EXIT --------------------------------Corte aqui 1998 FW - Corporation <><><><><><><><><><><><><>